Product Details:
Minimum Order Quantity | 1 Piece |
Type of display | LCD |
Display Size | 12.1 inch |
Brand | Konsung |
Model | Aurora |
Parameters Measured | ECG, Temperature, PR, SPO2 |
Suitable For | Neonatal, Adult, Pediatric |
No of Leads in ECG | 5 |
Pulse Rate Range | 20-200bpm |
Number of leads analyzed for ECG in single time | 5 |
Display waveform of Respiration | Yes |
SPO2 Measurement Technique | TruSignal |
SPO2 Measurement Range | 0-50% |
Type of SPO2 probe | Reusable |
NIBP Measurement Technique | Step Deflation Oscillometric |
NIBP Measurement range | 10-270 mmHg |
NIBP Cuff Supplied | Adult |
Supplied Temperature Probe | Skin |
Temperature probe type | Reusable |
Systolic BP - low and high alarm | Yes |
Diastolic BP - low and high alarm | Yes |
Mean BP - low and high alarm | Yes |
Heart rate - low and high alarm | Yes |
SPO2 - low and high alarm | Yes |
Respiratory rate - low and high alarm | Yes |
Temperature -low and high alarm | Yes |
Cuff leakage alarm | Yes |
Cuff disconnect alarm | Yes |
Low battery voltage indication | Yes |
Sensor/ wire/probe disconnection alarm | Yes |
Adjustable Alarm Volume | Yes |
Type of alarm | Visual |
Suspension of Alarm | Yes |
Ethernet port | Yes |
Wireless | Yes |
USB port | Yes |
Central Patient Monitoring Station Connectivity | Yes |
Inbuilt thermal Recorder/Printer | No |
Input Voltage | 220-240 V |
Phase | Single Phase |
Type of Battery backup | Lithium Ion |
AMC extension | Yes |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Type of display | LCD |
Display Size | 12.1inch |
Brand | Hwatime |
Model | Hawatime H8 |
Parameters Measured | NIBP, RESP, Temperature, SPO2, PR, ECG |
Suitable For | Neonatal, Adult, Pediatric |
No of Leads in ECG | 5 |
12 Lead interpretation of ECG | Yes |
Respiration Range | 7-120rpm(adult) 7-150rpm(neo/ped) |
Display waveform of Respiration | Yes |
NIBP Cuff Supplied | Adult |
SPO2 - low and high alarm | Yes |
Respiratory rate - low and high alarm | Yes |
Temperature -low and high alarm | Yes |
Cuff leakage alarm | Yes |
Cuff disconnect alarm | Yes |
Low battery voltage indication | Yes |
Sensor/ wire/probe disconnection alarm | Yes |
Adjustable Alarm Volume | Yes |
Type of alarm | Audio |
USB port | Yes |
Wall mount availability | Yes |
Weight | 4.5kg |
Model No | H8 |
Display Resolution | 800 x 600 mm |
Net Weight | 4.5 kg |
Monitor Size | 32 x 16 x 27 cm |
Surgery Mode | 100 dB |
Range | 250 BPM |
Accuracy | +/-3 BPM |
Voltage | AC 240 V |
Frequency | 60 Hz |
Battery | 1 Sealed Lithium Battery |
Additional Information:
Product Details:
Brand | Sinomed(Chinese) |
Type Of Medical Instrument | blood/infusion warmer |
Model Name/Number | Sinomed SH10 |
Usage/Application | Hospital |
Prevention and treatment of hypothermia in pre-, intra- and postoperative periods and its negative aftereffects. Infusion warming device is used during transfusion and infusion of blood, fluid therapy for children and adults, warming of nutrient solutions through a nasal or enteral probes.
Can be used in emergency rooms, intensive care units, etc.
Product Details:
Minimum Order Quantity | 10 Piece |
Type of display | LCD |
Display Size | 12.1 inch |
Brand | Contec |
Model | CMS 8000 |
Parameters Measured | Temperature, ECG, RESP, NIBP, SPO2 |
Suitable For | Neonatal, Pediatric, Adult |
Country of Origin | Made in India |
Display Type | TFT LCD |
Power Source | Battery |
Voltage | 210 V |
Frequency | 50 Hz |
Usage | Hospital |
Body Material | Plastic |
IP Rating | IP56 |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Type of display | LCD |
Display Size | 12.1 inch TFT LCD |
Brand | Comen |
Model | STAR8000E |
Parameters Measured | RESP, ECG, NIBP, Temperature, PR, SPO2 |
Suitable For | Neonatal, Pediatric, Adult |
No of Leads in ECG | 5 |
Pulse Rate Range | 20-200bpm |
Number of leads analyzed for ECG in single time | 5 |
Respiration Range | 7-120rpm(adult) 7-150rpm(neo/ped) |
Display waveform of Respiration | Yes |
SPO2 Measurement Technique | Nellcor |
SPO2 Measurement Range | 0-50% |
Type of SPO2 probe | Reusable |
NIBP Measurement Technique | Step Deflation Oscillometric |
NIBP Measurement range | 10-270 mmHg |
NIBP Cuff Supplied | Adult |
Supplied Temperature Probe | Skin |
Temperature probe type | Reusable |
Systolic BP - low and high alarm | Yes |
Diastolic BP - low and high alarm | Yes |
Mean BP - low and high alarm | Yes |
Heart rate - low and high alarm | Yes |
SPO2 - low and high alarm | Yes |
Respiratory rate - low and high alarm | Yes |
Temperature -low and high alarm | Yes |
Cuff leakage alarm | Yes |
Cuff disconnect alarm | Yes |
Low battery voltage indication | Yes |
Sensor/ wire/probe disconnection alarm | Yes |
Adjustable Alarm Volume | Yes |
Type of alarm | Audio |
Suspension of Alarm | Yes |
Ethernet port | Yes |
Wireless | Yes |
USB port | Yes |
Central Patient Monitoring Station Connectivity | Yes |
Inbuilt thermal Recorder/Printer | Yes |
Input Voltage | 220-240 V |
Phase | Single Phase |
Type of Battery backup | Lead Acid Battery |
AMC extension | Yes |
Wall mount availability | Yes |
Weight | 6 kg |
Power Source | Battery/mains |
Voltage | 220 V |
Frequency | 60 Hz |
Battery Capacity | 2 hours |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Brand | SIEMENS |
Model Name/Number | Servo 300 / 300A |
Ventilation Modes | A/C-PC Assist control (pressure control) A/C-VC Assist control (volume control) CPAP |
Patient Age Group | Neonatal, Adult, Paediatric |
Mounting Type | ICU |
Touch Screen Present | no |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Type of display | LCD |
Display Size | 12.1' |
Brand | Osen |
Model | Osen 8000 |
Parameters Measured | RESP, NIBP, PR, Temperature, ECG, SPO2 |
Suitable For | Neonatal, Adult, Pediatric |
No of Leads in ECG | 5 |
Pulse Rate Range | 20-200bpm |
12 Lead interpretation of ECG | Yes |
Number of leads analyzed for ECG in single time | 5 |
Respiration Range | 7-120rpm(adult) 7-150rpm(neo/ped) |
Display waveform of Respiration | Yes |
SPO2 Measurement Technique | TruSignal |
SPO2 Measurement Range | 0-100% |
Type of SPO2 probe | Reusable |
NIBP Measurement Technique | Step Deflation Oscillometric |
NIBP Measurement range | 10-270 mmHg |
NIBP Cuff Supplied | Adult |
Supplied Temperature Probe | Skin |
Temperature probe type | Reusable |
Systolic BP - low and high alarm | Yes |
Diastolic BP - low and high alarm | Yes |
Mean BP - low and high alarm | Yes |
Heart rate - low and high alarm | Yes |
SPO2 - low and high alarm | Yes |
Respiratory rate - low and high alarm | Yes |
Temperature -low and high alarm | Yes |
Cuff leakage alarm | Yes |
Cuff disconnect alarm | Yes |
Low battery voltage indication | Yes |
Sensor/ wire/probe disconnection alarm | Yes |
Adjustable Alarm Volume | Yes |
Type of alarm | Audio |
Suspension of Alarm | Yes |
Ethernet port | Yes |
Wireless | Yes |
USB port | Yes |
Central Patient Monitoring Station Connectivity | Yes |
Inbuilt thermal Recorder/Printer | No |
Input Voltage | 220-240 V |
Phase | Single Phase |
Type of Battery backup | Lithium Ion |
AMC extension | Yes |
Wall mount availability | Yes |
Accuarcy | +/-1% |
Resolution | 1 BPM |
Surgery | 20 Hz |
Rage | 240 BPM |
Dispaly Size | 12.1 inch |
Diagnostic Mode | 90 dB |
Offset Potential | +/-300 mV Leakage |
ECG Single Ragne | +/-5mV (vp-p) |
Model No | OSEN8000 |
Power Source | Battery/mains |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Type of display | LED |
Brand | Contec |
Model | CMS 5100 |
Parameters Measured | SPO2, NIBP, Temperature |
Suitable For | Neonatal, Pediatric |
Weight | 1.6KG |
Method | Oscillometry |
Model No | CMS5100 |
Mode | Manual/ Auto/ Continuous |
Resolution | 1 mm Hg |
NIBP Accuracy | 5+/- mm Hg |
Alarm | Systolic/ Diastolie/ Map |
Measurement Range | 100 % |
Dimensions without Stand | 191 x 160 x 244 mm |
Net Weight | 1.5 kg |
Additional Information:
Product Details:
Minimum Order Quantity | 01 Piece |
Type of display | TFT |
Display Size | 10.4" |
Brand | Hwatime |
Model | XM-750 |
Parameters Measured | Temperature, NIBP, ECG, SPO2, RESP, PR |
Suitable For | Adult, Neonatal, Pediatric |
No of Leads in ECG | 5 |
Pulse Rate Range | 20-200bpm |
12 Lead interpretation of ECG | Yes |
Number of leads analyzed for ECG in single time | 5 |
Arrhythmia detection | Yes |
Display waveform of Respiration | Yes |
SPO2 Measurement Technique | Masimo |
SPO2 Measurement Range | 0-100% |
Type of SPO2 probe | Reusable |
NIBP Measurement Technique | Step Deflation Oscillometric |
NIBP Measurement range | 10-270 mmHg |
NIBP Cuff Supplied | Adult |
Supplied Temperature Probe | Skin |
Temperature probe type | Reusable |
Systolic BP - low and high alarm | Yes |
Diastolic BP - low and high alarm | Yes |
Mean BP - low and high alarm | Yes |
Heart rate - low and high alarm | Yes |
SPO2 - low and high alarm | Yes |
Respiratory rate - low and high alarm | Yes |
Temperature -low and high alarm | Yes |
Cuff leakage alarm | Yes |
Cuff disconnect alarm | Yes |
Low battery voltage indication | Yes |
Sensor/ wire/probe disconnection alarm | Yes |
Adjustable Alarm Volume | Yes |
Type of alarm | Audio |
Suspension of Alarm | Yes |
Ethernet port | Yes |
Wireless | Yes |
USB port | Yes |
Inbuilt thermal Recorder/Printer | No |
Input Voltage | 220-240 V |
Phase | Single Phase |
Type of Battery backup | Lithium Ion |
AMC extension | Yes |
Wall mount availability | Yes |
Model No | XM750 |
Power Source | Electric |
Voltage | 240 V |
Frequency | 60 Hz |
Warranty | 1 Year |
Body Material | Plastic |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Unit |
Brand | Bistos |
Model Name/Number | BT- 350 |
Machine Condition | New |
LCD Display | 7 inch |
Foldable Screen | Yes |
FHR Range | 210 BPM |
Warranty | 1 Year |
Is It Portable | Portable |
Supply Voltage | 50 Hz |
Supply Frequency | 240 V |
Product Details:
Minimum Order Quantity | 1 Piece |
Type of display | LCD |
Display Size | 10.4" |
Brand | Comen |
Model | C-50 |
Parameters Measured | SPO2, Temperature, NIBP, ECG, RESP, PR |
Suitable For | Adult, Pediatric, Neonatal |
No of Leads in ECG | 5 |
Pulse Rate Range | 20-200bpm |
12 Lead interpretation of ECG | Yes |
Number of leads analyzed for ECG in single time | 5 |
Respiration Range | 7-120rpm(adult) 7-150rpm(neo/ped) |
Display waveform of Respiration | Yes |
SPO2 Measurement Technique | Nellcor |
SPO2 Measurement Range | 0-100% |
Type of SPO2 probe | Reusable |
NIBP Measurement Technique | Step Deflation Oscillometric |
NIBP Measurement range | 10-270 mmHg |
NIBP Cuff Supplied | Adult |
Supplied Temperature Probe | Skin |
Temperature probe type | Reusable |
Systolic BP - low and high alarm | Yes |
Diastolic BP - low and high alarm | Yes |
Mean BP - low and high alarm | Yes |
Heart rate - low and high alarm | Yes |
SPO2 - low and high alarm | Yes |
Respiratory rate - low and high alarm | Yes |
Temperature -low and high alarm | Yes |
Cuff leakage alarm | Yes |
Cuff disconnect alarm | Yes |
Low battery voltage indication | Yes |
Sensor/ wire/probe disconnection alarm | Yes |
Adjustable Alarm Volume | Yes |
Type of alarm | Audio |
Ethernet port | Yes |
Wireless | Yes |
USB port | Yes |
Central Patient Monitoring Station Connectivity | Yes |
Inbuilt thermal Recorder/Printer | No |
Input Voltage | 220-240 V |
Phase | Single Phase |
Type of Battery backup | Lead Acid Battery |
AMC extension | Yes |
Wall mount availability | Yes |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Brand | Comen |
Model Name/Number | Star 5000E |
Machine Condition | New |
Thermal Printer | In-built |
LCD Display | 5.7" |
Foldable Screen | Yes |
FHR Range | 50-210bpm |
Warranty | 1 Year |
Is It Portable | Portable |
FHR Frequency | 2MHz |
Battery Backup | Yes |
Product Details:
Minimum Order Quantity | 1 Piece |
Type of display | TFT |
Display Size | 12 inch / 15 inch |
Brand | Comen |
Model | C-80 |
Parameters Measured | RESP, PR, SPO2, NIBP, Temperature, ECG |
Suitable For | Adult |
No of Leads in ECG | 12 |
Pulse Rate Range | 15-300bpm |
Arrhythmia detection | Yes |
Wireless | Yes |
USB port | Yes |
Inbuilt thermal Recorder/Printer | Yes |
Type of Battery backup | Lithium Ion |
Wall mount availability | Yes |